Needleless Positive Pressure Infusion Connector Straight Type

We Can Create Unique Designs Springs that Are Outside Of The Industry Standard.

Springs Manufacturer

Bajaparts Springs, LLC is dedicated to becoming the spring supplier of choice through our customer-focused approach to product quality, open communication, technical service and on-time delivery. Through Bajaparts's commitment to our employees and investment in the latest spring manufacturing technology, we have expanded our capabilities beyond the typical compression, extension and torsion spring product mix. We think outside of the box and get excited to work on unique designs that are outside of the industry standard.

  • Needleless Connectors - Lynn Hadaway Associates, Inc

    Needleless Connectors - Lynn Hadaway Associates, Inc

    Although needleless connectors serve that purpose, their use has been associated with an increase in such complications as catheter-related bloodstream infection and catheter lumen occlusion. Complications may be related to design characteristics, user knowledge deficits, poor practices, or some combination thereof.

  • MaxZero needleless connector - Becton Dickinson

    MaxZero needleless connector - Becton Dickinson

    The connector helps maintain line patency without positive pressure flushing and clamping. Proven three-second disinfection A solid, sealed surface helps prevent contamination from entering the line. Bacteria has nowhere to hide The visible fluid path and high flow straight fluid channels enhance flushing.

  • CN101879339A - Needleless dosing positive pressure ...

    CN101879339A - Needleless dosing positive pressure ...

    The invention relates to a needleless dosing positive pressure connector. The positive pressure connector can be mainly used for liquid injection, gravity transfusion and liquid extraction and is connected with a venous transfusion tube, ductus venosus and …

  • Needleless Connectors: Improving Practice, Reducing Risks ...

    Needleless Connectors: Improving Practice, Reducing Risks ...

    Positive displacement needleless connectors require clamping after syringe disconnection. Blood reflux can still occur with these devices, especially if the empty fluid container is not disconnected immediately. This type of needleless connector holds a larger amount of fluid than the negative displacement type.

  • Needleless Connectors and the Improvement of Patient and ...

    Needleless Connectors and the Improvement of Patient and ...

    Dec 09, 2013 · While needleless connectors were initially developed to help improve healthcare professional safety, in recent years the use of needleless connectors may have contributed to improved patient care as well. Guidelines The Food and Drug Administration (FDA) has regulatory authority over the marketing of needleless connectors.

  • MaxPlus clear needleless connector - BD

    MaxPlus clear needleless connector - BD

    MaxPlus™ clear needleless connector. Promotes compliance with best practices and aseptic technique. Positive displacement helps reduce reflux occlusions at disconnection. Saline only flush reduces use of heparin and associated risks. Pressure rated to 325 psi at a flow rate of 10 mL/second.

  • China Needleless Connector Positive Pressure - China ...

    China Needleless Connector Positive Pressure - China ...

    1. design of positive pressure avoids back flow of blood during removal of syringe, this will help to prevent blood clot at the catheter tip inside the blood vessel. 2. The housing is impregnated with PC Ag+ which helps to lower infection. 3. Protruding design of the stalk at the injection port follows infection control protocol. 4.

  • Know your connectors…. | Infusion Nurse Blog

    Know your connectors…. | Infusion Nurse Blog

    Aug 06, 2010 · Positive Fluid Displacement – connectors with mechanical valves are designed to produce a positive fluid displacement upon disconnection of the IV set or syringe. Upon disconnection, the fluid in the valve is pushed out to the catheter lumen to remove the blood that has refluxed.

  • TITLE: Positive versus Negative Needleless Connectors for ...

    TITLE: Positive versus Negative Needleless Connectors for ...

    Positive versus Negative Needleless Connectors for Central Venous Lines and Peripheral Lines 2. The major difference in the use of the NFD and the PFD devices is that the NFD device is clamped before the syringe is disconnected, whereas the PFD device is not clamped until after the syringe is disconnected.2.

  • WO2017016092A1 - Positive pressure needle-free injection y ...

    WO2017016092A1 - Positive pressure needle-free injection y ...

    A positive pressure needle-free injection Y-type connector device (100), comprising a Y-type tube (1) and an elastic sealing component (2), the Y-type tube (1) being provided with a limiting portion (123) and a needleless injection interface portion (125), the needleless injection interface portion (125) being provided with an injector interface (126) substantially matching a needleless injector, the elastic …

  • One Link

    One Link

    • Connectors not designed to tolerate pressures used for power injection can fail and harm the patient.3 • 8Failure can delay treatment of patient. Training Requirements • Multiple connectors with varied techniques can cause confusion and increased potential for errors.9 • 9IV needleless connectors have become complex in design.

  • What you should know about needleless I.V. systems ...

    What you should know about needleless I.V. systems ...

    Marketed as “saline only” flush devices, they don't require 100% compliance with positive-pressure flushing technique or catheter clamping after infusion. Because some of these caps have a slight taper at the luer connection, make sure that all tubes and syringes are correctly connected so they don't leak.

  • IV Tubing, Connectors, Securement and Accessories

    IV Tubing, Connectors, Securement and Accessories

    Needleless Caps/Connectors. Our portfolio of needles IV connectors include the innovative, first-to-market antimicrobial IV connector; the V-LINK Luer-Activated device with VITALSHIELD antimicrobial coating.We also offer the CLEARLINK Luer-Activated system and …

  • IV Administration Products

    IV Administration Products

    Needleless connectors offer a safe way to access IV lines without the use of a needle, which greatly reduces the risk of accidental needlestick injuries. B. Braun offers a variety of needleless connector devices to meet the desired need of individual facilities.

  • MCAII TTLs Flashcards | Quizlet

    MCAII TTLs Flashcards | Quizlet

    The correct sequence for a negative fluid pressure needleless connector is to flush, keep pressure on syringe, close the clamp, and remove syringe from injection port. With a neutral displacement valve needleless connector there is no required sequence for disconnecting the …

  • IV Extension Sets | Bound Tree

    IV Extension Sets | Bound Tree

    Curaplex needle-free administration and extension sets utilize MicroClave® neutral displacement technology, creating a safe, protective barrier in the IV connector. This set serves to lessen the risk of bacterial contamination or infection during procedures.

  • Needleless Customized Positive Pressure Infusion Connector

    Needleless Customized Positive Pressure Infusion Connector

    1. design of positive pressure avoids back flow of blood during removal of syringe, this will help to prevent blood clot at the catheter tip inside the blood vessel. 2. The housing is impregnated with PC Ag+ which helps to lower infection. 3. Protruding design of the stalk at the injection port follows infection control protocol. 4.

  • BD SmartSite™ Needle-Free Connector - BD

    BD SmartSite™ Needle-Free Connector - BD

    The SmartSite connector has the same proximal and distal connectors as the Alaris Pump module and gravity administration set Y-ports, enabling standardization. Straight fluid pathway The pathway design makes flushing easier and reduces the risk of hemolysis.

  • FDA Alert | IV-Therapy.net

    FDA Alert | IV-Therapy.net

    Summary of the Problem. Needleless connectors may also be referred to as “valves” or “accesses.” “Positive displacement” refers to the positive pressure of fluid movement from a reservoir into the lumen of the catheter upon disconnection of an administration set or syringe. FDA has received three reports of death associated with BSI...

  • (PDF) Needleless Connectors - ResearchGate

    (PDF) Needleless Connectors - ResearchGate

    Needleless Connectors. Within the past 20 years there has been an explosion of devices designed to allow connection of multiple intravenous sets and catheter hubs without the use of needles. Currently, the number of devices, their internal and external designs, and their functions can be quite confusing.

  • Needleless Connectors: Improving Practice, Reducing Risks

    Needleless Connectors: Improving Practice, Reducing Risks

    Results: The specific type of needleless connector being used was unknown by 25% and correct clamping sequence was chosen by 52.8% of respondents. The majority, 94.3% reported that they always clean these devices before each use, how- ever there are differences in technique.

  • CVAD adjuncts to IV administration sets | ICNSW

    CVAD adjuncts to IV administration sets | ICNSW

    A positive-pressure flushing technique is required when a negative-displacement device is used (see common needleless connectors table). A positive displacement needleless injection system will reserve a small amount of fluid to push toward the catheter tip at disconnection of the syringe or tubing, which prevents blood from remaining inside ...

  • Positive Pressure Needle Free Connector, Positive Pressure ...

    Positive Pressure Needle Free Connector, Positive Pressure ...

    Alibaba.com offers 204 positive pressure needle free connector products. About 26% of these are injection & puncture instrument, 1% are medical adhesive, and 1% are dressings and care for materials. A wide variety of positive pressure needle free connector …

  • FDA Alert: Positive Displacement Needleless Connectors ...

    FDA Alert: Positive Displacement Needleless Connectors ...

    Aug 05, 2010 · FDA Alert: Positive Displacement Needleless Connectors infusionnurse / August 5, 2010 Yet another FDA Alert – this time on positive displacement needleless connectors – a device all nurses are very familiar with and use on a daily basis on patients requiring infusion therapy.

  • Needle Free Positive Pressure Infusion Connector Straight Type

    Needle Free Positive Pressure Infusion Connector Straight Type

    Needle Free Positive Pressure Infusion Connector Straight Type , Find Complete Details about Needle Free Positive Pressure Infusion Connector Straight Type,Needle Free,Needle Free Positive Pressure,Needle Free Infusion from General Medical Supplies Supplier or …

  • Needleless Negative Pressure Medical Devices Straight Type ...

    Needleless Negative Pressure Medical Devices Straight Type ...

    Needleless Negative Pressure Medical Devices Straight Type , Find Complete Details about Needleless Negative Pressure Medical Devices Straight Type,Needleless,Needleless Negative Pressure,Medical Adapter from Supplier or Manufacturer-CHI FENG CO., LTD.

  • CareFusion MaxPlus Tru-Swab Clear Needleless Positive ...

    CareFusion MaxPlus Tru-Swab Clear Needleless Positive ...

    CareFusion MaxPlus Tru-Swab Clear Needleless Positive Displacement Connector is designed for use on all patients requiring IV therapy, the MaxPlus clear needleless connector assists facilities in enhancing the clinical best practices of priming, swabbing and flushing.

  • Needleless Connectors-What’s the Real Story? - ACLS | PALS

    Needleless Connectors-What’s the Real Story? - ACLS | PALS

    Mar 10, 2013 · Needleless connectors are known in the nursing worlds as “injection ports” or “claves.” “Positive displacement” refers to the positive pressure of fluid movement from a reservoir into the lumen of the catheter upon disconnection of an …

  • Positive Pressure - The Truth! | IV-Therapy.net

    Positive Pressure - The Truth! | IV-Therapy.net

    Oct 23, 2008 · I am in a continuous state of disbelief surrounding the various "experts" that are constantly negating the true benefits of positive pressure connectors. I am a seasoned clinician, researcher, and have been following this topic for many years. Each and every hospital that I have worked at has had nothing but positive results from utilizing positive pressure devices.

  • BD MaxPlus™ Needle-Free Connector - BD

    BD MaxPlus™ Needle-Free Connector - BD

    Choose the only needle-free connector with an FDA-cleared label statement demonstrating a reduction in CLABSI Hospitals using the MaxPlus ™ needle-free connector had lower unadjusted CLABSI rates, as well as lower standardized infection ratios, compared to hospitals not using the MaxPlus connector.*

  • TITLE: Positive versus Negative Needleless Connectors for ...

    TITLE: Positive versus Negative Needleless Connectors for ...

    Positive versus Negative Needleless Connectors for Central Venous Lines and Peripheral Lines 4. stopcock group) who required central venous catheter and arterial catheter placement for a duration of greater than 48 hours during their ICU stay at a university …

  • The effects of needleless connectors on catheter-related ...

    The effects of needleless connectors on catheter-related ...

    Needleless connectors provide needleless access at the hub end of the catheter for intravenous medication administration, fluid infusion, or withdrawal of blood samples or to connect administration sets to the intravascular catheters. Needleless connectors include the split septum connectors and the luer-activated mechanical valves.

  • Central venous Device Access | Science Flashcards | Quizlet

    Central venous Device Access | Science Flashcards | Quizlet

    Start studying Central venous Device Access. Learn vocabulary, terms, and more with flashcards, games, and other study tools. ... depending on the type, can remain in place for several weeks to years. ... Whether the needleless connector is a positive-pressure connector or negative-pressure connector will determine whether the clamping occurs ...

  • Medical Positive Pressure Needle Free Infusion Connector ...

    Medical Positive Pressure Needle Free Infusion Connector ...

    Medical parts accessories Positive Pressure needle free connector, infusion needleless connector Used for I. 2. By Road: Domestic and neighbour country : 3-10 days 3. By Sea : 5-45 day all over the world. Loading port : Shenzhen, Yantian, Shekou, Hong Kong, Xiamen, Ningbo, Shanghai, Nanjing, Qingdao According to your requirement.

  • comparison and function of positive, negative and neutral ...

    comparison and function of positive, negative and neutral ...

    It is a positive displacement needleless connector. This means that when a syringe or other male luer lock device is removed from the Ultrasite, a small amount of fluid is moved into the lumen of the catheter, preventing blood reflux. However, when a syringe is connected to …

  • Peripherally inserted central venous catheters (PICCs)

    Peripherally inserted central venous catheters (PICCs)

    needleless connector, using a twisting motion, for a minimum of 15 seconds. 5. Allow the needleless connector to dry. 6. Access the needleless connector with the syringe or IV tubing, opening the clamp, if necessary. 7. Wash your hands again when you are done. Key steps for changing needleless connectors

  • Positive Pressure Needle Free Connector_ Life Medical ...

    Positive Pressure Needle Free Connector_ Life Medical ...

    FeaturesBenefits: 1.Patent design of positive pressure avoids back flow of blood during removal of syringe. This will help to prevent blood clot at the catheter tip inside the blood vessel. 2.The housing is impregnated with PC Ag+ which hel

  • IV therapy 1 Flashcards | Quizlet

    IV therapy 1 Flashcards | Quizlet

    The male Luer lock has threads that secure and lock the connectors. Taping connectors is not acceptable practice. The slide clamp does not secure connectors but regulates the rate. A slip lock is a type of male adapter that slips into the female end of the equipment; however, there is no mechanism to secure the two pieces of equipment.

  • Clave IV Connector Technology | ICU Medical

    Clave IV Connector Technology | ICU Medical

    Each of ICU Medical’s needlefree connectors utilizes the same Clave infection control technology, designed to enhance patient safety. Clave’s straight fluid path and minimal residual volume help maximize the effectiveness of every flush.

  • I.V. Therapy Accessories - McKesson Medical-Surgical

    I.V. Therapy Accessories - McKesson Medical-Surgical

    For Needleless Connectors CFF1-270 (1) For Needleless Connectors CFF10-250 (1) For Needleless Connectors CFJ1-270 (1) For Needleless Connectors CFJ5-250 (1) For PICC Lines, Drain Tubes, Catheters (1) For Peripheral Catheters, Arterial, and central Venous Catheters to Administer IV fluids or medication or to aspirate blood (2)

  • Needleless Negative Pressure Infusion Devices Straight Type

    Needleless Negative Pressure Infusion Devices Straight Type

    Needleless Negative Pressure Infusion Devices Straight Type, US $ 0.3 - 0.33 / Piece, Medical Polymer Materials & Products, Taiwan, China, CHI FENG.Source from CHI ...

  • Disposable Medical Standard Needleless Injection Luer Lock ...

    Disposable Medical Standard Needleless Injection Luer Lock ...

    The positive tip of the connector could be connector with other connector freely. 3. When pulling the needle out, the piston will supply a postive pressure towards vascular access continually ,and it will prevent blood reflux, thrombus formation and clotting block. 4. It is with powerful anti-infection ability.

  • Choosing the Best Design for Intravenous Needleless ...

    Choosing the Best Design for Intravenous Needleless ...

    Jul 28, 2010 · Choosing the Best Design for Intravenous Needleless Connectors to Prevent Bloodstream Infections. July 28, 2010. Infusion & Vascular ... Clinicians often are faced with several types of NCs in use at their hospital or healthcare system. ... the clinician clamps the IV catheter and then disconnects the NC. In contrast, with positive pressure NCs ...

  • Keeping I.V. therapy safe with needleless systems ...

    Keeping I.V. therapy safe with needleless systems ...

    A slit silicone disk within the catheter hub has three positions: closed, open for infusion, and open for aspiration. Because it takes about 10 inches (25 cm) of fluid to open the valve for infusion, catheters can’t occlude when an unattended infusion runs dry. Four to five times greater pressure is required to open the valve for aspiration.

  • The Long and Short of Needleless IV Extension Sets - CanadiEM

    The Long and Short of Needleless IV Extension Sets - CanadiEM

    Needleless IV tubing and extension sets were introduced in the early 1990s to combat workplace needlestick injuries and leaky ports. 1 Many types were created and marketed by manufacturers, though ultimately they all provide a non-sharp connection to add lines to an IV. However, the added safety for medical staff had unintended consequences on the functionality of the tubing.

  • China Needleless Connector Positive Pressure with High ...

    China Needleless Connector Positive Pressure with High ...

    1.design of positive pressure avoids back flow of blood during removal of syringe, this will help to prevent blood clot at the catheter tip inside the blood vessel. 2. The housing is impregnated with PC Ag+ which helps to lower infection. 3. Protruding design of the stalk …

  • CHI FENG CO., LTD. - Needleless connector, Medical Device

    CHI FENG CO., LTD. - Needleless connector, Medical Device

    CHI FENG CO., LTD., Experts in Manufacturing and Exporting Needleless connector, Medical Device and 112 more Products. A Verified TW Gold Supplier on Alibaba.com.

  • Keeping I.V. therapy safe with needleless systems ...

    Keeping I.V. therapy safe with needleless systems ...

    Because this system has a “dead space” to accommodate the cannula, failing to properly use a positive-pressure flush technique or a clamp on the system connection can allow blood to back up into the patient’s infusion catheter, increasing the risk of interruptions in …

  • NURSING POLICY/ PROCEDURE MANUAL TITLE: Port-A …

    NURSING POLICY/ PROCEDURE MANUAL TITLE: Port-A …

    NURSING POLICY/ PROCEDURE MANUAL ... All inpatients with an accessed IVAD will have a needleless positive pressure central line adaptor/cap (CLC 2000™) applied. 6. According to the site specific Infection Control Policy & Procedure change: ... connector to transfer blood from syringe to blood tubes. F- BLOOD CULTURES .

  • China Positive Pressure Needless Connector - China ...

    China Positive Pressure Needless Connector - China ...

    1. design of positive pressure avoids back flow of blood during removal of syringe, this will help to prevent blood clot at the catheter tip inside the blood vessel. 2. The housing is impregnated with PC Ag+ which helps to lower infection. 3. Protruding design of the stalk at the injection port follows infection control protocol. 4.

  • Choosing the Best Design for Intravenous Needleless ...

    Choosing the Best Design for Intravenous Needleless ...

    Jul 28, 2010 · Both also increase the risk of HA-BSI. Blood reflux can occur with both positive and negative pressure luer access mechanical valve NCs. Preferable: A luer access mechanical valve NC with little or no blood reflux. Flushing solution. Some NC types are designed to be flushed with heparin to reduce the risk of occlusion.

  • SmartSite® Needle-Free Valve, Infusion | Smiths Medical

    SmartSite® Needle-Free Valve, Infusion | Smiths Medical

    The SmartSite® Needle-Free Valve is one of the most widely used needle-free systems in the world. The patented SmartSite® Valve is a swabable, capless, 2-way valve for injection/gravity/pump flow or aspiration of fluids.